Cooldt calculate the cooling duration of a multi-layers pipe in a cold environment. The duration to reach the “Final fluid temperature” or cool-down time (CDT) is calculated by solving the heat equation in cylindrical coordinates with a flux conservative formulation.

Features

  • Flux Conservative Formulation of Transient Heat Transfer
  • Automatic meshing and time step calculation (0.1% accuracy)
  • LibreOffice and Excel interfaces
  • Excel Add-in
  • Gnuplot Compatible Output
  • 32 and 64 bits versions